      Suction cup P-D36 Silicone 1/4" NPT male composite, detectable, FCM , 0207035

      0207035

      article n° 0207035

      • The silicone material complies with FDA 21 CFR 177.2600 and EU 1935/2004.
      • Long lasting high-end silicone material
      • A low percentage metal additive (Fe) is mixed with the rubber material to make it detectable.
      • Suitable for pralines, such as chocolates
      • Available with male threaded food grade, detectable plastic fittings or acid proof stainless steel fittings.
      • Easy to clean with hygienic design. No dust/dirt pockets.
      Métrique   Impérial
      Généralités
      Curve radius 37 mm
      Application FDA détectable
      Tailles des fixations 1/4"
      Genre de la fixation Mâle
      Type de fixation Filetage NPT
      Options de fixation Aucun
      Matériaux Silicone (SIL détectable FCM), Composite
      Modèle de ventouse P-D
      Forme Profonde
      Couple de serrage max 13 Nm
      Volume 15 cm³
      Masse 13,7 g
      Dimensions
      Hauteur 46,3 mm
      Diamètre extérieur 35,8 mm
      Performances - forces de levage
      Force de levage perpendiculaire Force de levage parallèle
      10 -kPa 4,5 N 12,2 N
      20 -kPa 8,6 N 16,8 N
      40 -kPa 19 N 28,3 N
      Matériaux
      Silicone (SIL détectable FCM)
      Couleur Bleu
      Dureté 40 °Shore A
      Température -40 – 200 °C
      Résistance des matériaux
      Silicone (SIL détectable FCM)
      Alcool ++
      Acides concentrés -
      Éthanol N/A
      Hydrolyse +
      Méthanol N/A
      Huiles -
      Oxydation +++
      Pétrole -
      Résistance à l’usure ++
      Climat & ozone +++

      Schémas dimensionnels

      Veuillez vous connecter ou Inscription pour voir les schémas dimensionnels

      pièces détachées
      article n°
      Suction cup P-D36 Silicone detectable, FCM 0206372
      Fitting 1/4"NPT Male, composite, F-BX25-35 P-D36 0207152

      Accessoires / Pièces détachées
      article n°
      Fitting 3/8"NPT Male, composite, F-BX25-35 P-D36 0207154
      Fitting G3/8" Male, composite, F-BX25-35 P-D36 0207153
      Fitting 1/4"NPT Male, composite, F-BX25-35 P-D36 0207152
      Fitting G1/4" Male, composite, F-BX25-35 P-D36 0207151
      Fitting 3/8"NPT Male, SS, F-BX25-35 P-D36 0207150
      Fitting G3/8" Male, SS, F-BX25-35 P-D36 0207149
      Fitting 1/4"NPT Male, SS, F-BX25-35 P-D36 0207148
      Fitting G1/4" Male, SS, F-BX25-35 P-D36 0207147
      Support
      Formation (3)
        • Ventouses

          • Comment doit-on stocker les ventouses Piab ?
          • How do I know which lifting forces I need?
            • It depends on the weight of the product that should be lifted and how many suction cups that can be used for the object. Calculate the weight to be lifted per suction cup and then take the weight multiplied with the gravity force (g=9.81) and you have the lifting force needed in Newton (N)

          • How do I know which suction cup to choose?
            • Our recommendation is to start at the application listing to find the products we recommend to different applications. If you have questions please do not hesitate to contact our partners to find the optimum solution.

          • I have a variation of number of objects to be lifted- how can I make sure to not drop them or to use too much energy? How to optimize this type of system?
            • All suction cups not in contact with an object (open) will draw in a lot of air and demand a larger pump than actually necessary. By using different valves, such as piSAVE sense, in the suction cups, the suction cups will be normally closed until they come in contact with the handled object. Only the cups needed in the specific lifting cycle will be open and flow air. Please see the video piSAVE sense.

          • What is DURAFLEX®?
            • DURAFLEX® is a patented material specially developed to feature the elasticity of rubber and the wear resistance of polyurethane. The DURAFLEX® material is mark-free.

        Demande de devis

        Veuillez vous connecter ou Inscription d'abord pour demander un devis

        Créez votre compte GRATUIT et accédez au contenu complet:

        • Fichiers CAD
        • Disponibilités produits
        • Demandes de prix
        • Livres blancs
        • Newsletter
        Créer mon compte!
        My Piab
        Dernières activités
        Comparaisons de produits

        Piab AB © 2016 Mentions légales

        Suivez-nous

        Contactez-nous