Gives the possibility to bring the C56 conveyor series to the premium piFLOW®p platform.
Read moreFeed pressure | Air consumption | Vacuum flow (scfm) at different vacuum levels (-inHg) | Max vacuum | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | scfm | 0 | 2 | 5 | 8 | 11 | 14 | 17 | 20 | 23 | 26 | -inHg |
58 | 169.51 | 665.33 | 368.69 | 258.51 | 163.16 | 108.064 | 55.091 | 13.56 | 0 | 0 | 0 | 17.72 |
72.5 | 203.41 | 707.71 | 415.3 | 298.76 | 190.7 | 114.42 | 84.76 | 47.46 | 24.37 | 0 | 0 | 20.67 |
87 | 237.32 | 720.43 | 449.21 | 351.74 | 230.96 | 122.9 | 80.52 | 67.8 | 47.46 | 0 | 0 | 22.15 |
Feed pressure | Air consumption | Evacuation time (s/cf) to reach different vacuum levels (-inHg) | Max vacuum | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
psi | scfm | 2 | 5 | 8 | 11 | 14 | 17 | 20 | 23 | 26 | -inHg |
58 | 2265.34 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 17.72 |
72.5 | 2718.41 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 20.67 |
87 | 3171.48 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 22.15 |
Different product types can’t be compared. Do you want to remove the existing products?