Item number: P3010_AVM™2
P3010 AVM™2
Compact/stackable vacuum pumps are air-driven multistage ejector families, based on COAX® technology, that come with integrated controls and special functions,...
Read more
Login or create account to access all our content and features!
Features
- Patented multistage COAX® cartridge - MINI - with Pi, Si, Xi cartridge.
- AVM™2, Automatic Vacuum Management, unit with built-in control and monitoring functions.
- Valves for vacuum on/off, blow-off, blow-off flow control and non-return valve.
- Option with Normally Closed "fail safe" on/off valve (NC). It changes to an open valve if power is lost and vacuum will be generated. A conventional normally closed on/off valve (NC 2) is also available. It stays closed if electrical power is lost or removed.
- Option with automatic blow-off (1 sec) reduces number of outputs needed from PLC or I/O box.
- Analogue vacuum sensor with two digital outputs.
- Digital display with “-kPa” or “-inHg” as unit options.
- Integrated energy saving function (ES) that minimizes the air consumption in sealed systems. The ES function can be activated manually or via a signal (signal override).
- Three-colour LED status indicators for valves, signal outputs and ES.
Automotive
Packaging
- Direct food contact
- Rotary carton feeding
- Tray forming, tray unloading and loading
- Vacuum belt feeding
General
Material
Al , Nitrile (NBR) , PA , PMMA , SS
Noise level
66 - 68 dBA
Temperature
0 - 50 °C
Weight
250 - 330 g
Electrical data
Current, consumption (nominal)
110 mA
Current, output (max. outplut load)
40 mA
Display
LED indicators, numeric
Ripple, max.
1 V_rms
Safety classification
IP65 [NEMA 4]
Supply voltage
22 - 28 VDC
Supply voltage, nominal
24 VDC
Performance
Feed pressure, max.
0.7 MPa
Pneumatic data
Vacuum flow, range (blow-off)
0 - 7.5 Nl/s
Signal function
Hysteresis
7±1 kPa
Signal range
20 - 80 -kPa
Feed pressure | Air consumption | Vacuum flow (Nl/s) at different vacuum levels (-kPa) | Max vacuum | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
MPa | Nl/s | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | -kPa |
0.6 | 0.79 | 1.6 | 1 | 0.5 | 0.41 | 0.36 | 0.28 | 0.17 | 0.05 | 0.01 | 0 | 83 |
0.6 | 0.44 | 1.34 | 0.73 | 0.55 | 0.35 | 0.23 | 0.17 | 0.13 | 0.08 | 0 | 0 | 75 |
0.32 | 0.44 | 1.4 | 0.6 | 0.44 | 0.27 | 0.19 | 0.14 | 0.1 | 0.06 | 0.03 | 0 | 90 |
0.6 | 0.54 | 1.45 | 0.79 | 0.53 | 0.42 | 0.3 | 0.16 | 0.11 | 0.08 | 0.01 | 0 | 93 |
0.5 | 0.46 | 1.43 | 0.7 | 0.5 | 0.33 | 0.19 | 0.15 | 0.11 | 0.07 | 0.045 | 0.011 | 94 |